Summary
Adults in the OptimPacing trial had a lower risk of death, hospitalization for heart failure, or pacing-induced cardiomyopathy with left bundle branch pacing than with right ventricular pacing, the American Heart Association said. The randomized trial compared a technique that uses the heart’s own electrical pathway with the standard pacing approach for heart block.
Key Takeaways
- At 4 years, the estimated rate of death, heart failure hospitalization, or pacing-induced cardiomyopathy was 8.5% with left bundle branch pacing vs 19.2% with right ventricular pacing.
- The OptimPacing trial randomized 685 adults with second-degree or complete atrioventricular block or with ongoing atrial fibrillation and a slow, symptomatic heart rate.
- An independent data monitoring committee and the trial’s steering committee recommended ending OptimPacing early after left bundle branch pacing met the prespecified threshold for superiority.
The American Heart Association reported that left bundle branch pacing was associated with a 59% lower risk of death, heart failure hospitalization, or pacing-induced cardiomyopathy than right ventricular pacing in its Scientific Sessions release on Nov 8, 2026. The findings were presented at Scientific Sessions 2026 in Chicago, and the full manuscript was published the same day in the New England Journal of Medicine.
Right ventricular pacing, the standard pacemaker approach for heart block, sends electrical signals to the right ventricle. Left bundle branch pacing delivers the signal to part of the heart’s own electrical pathway, following the natural sequence of activation so the ventricles contract in a more coordinated pattern.
At 4 years, an estimated 8.5% of participants assigned to left bundle branch pacing had died, been hospitalized for heart failure, or developed pacing-induced cardiomyopathy, compared with 19.2% of those assigned to right ventricular pacing. No participants in the left bundle branch pacing group developed pacing-induced cardiomyopathy, compared with 11.7% in the right ventricular pacing group. Heart failure hospitalization occurred in 1.5% vs 2.9%, respectively.
An independent data monitoring committee reviewed the results at a planned interim analysis after a median follow-up of 3 years. That committee and the trial’s steering committee recommended stopping the trial early because left bundle branch pacing met the prespecified threshold for superiority.
“We expected that the group with left bundle branch pacing would do better than the group with right ventricular pacing. However, the difference between the two groups was greater than we expected,” says study author Jiangang Zou, MD, PhD, a professor of cardiology at First Affiliated Hospital, Nanjing Medical University in Nanjing, China, in a release.
OptimPacing ran at 17 centers in mainland China, Hong Kong, the UK, Poland, and the US from June 2021 to January 2025. Investigators randomized 685 adults equally between the two pacing groups; the mean age was 68.4 years, and 57.5% were men. Participants had second-degree or complete atrioventricular block or ongoing atrial fibrillation with an average heart rate below 50 beats per minute and related symptoms.
Investigators collected data before randomization, immediately after implantation, at 6 and 12 months, and annually thereafter. They tracked deaths, heart failure hospitalizations, pacing-induced cardiomyopathy, other safety events, heart ultrasound results, and pacemaker data. An independent committee reviewed and confirmed major health events without knowing participants’ treatment assignments.
The American Heart Association noted that stopping the trial early could overestimate the benefit of left bundle branch pacing and reduce the precision of the estimates. Most participants started with normal left ventricular ejection fraction, so the findings may not apply to people with reduced heart function. All left bundle branch procedures used the same type of lead, and it is not known whether the results apply to other pacing tools.
Zou called for further research to determine which patients are best suited to each pacing technique, compare approaches that use the heart’s natural electrical system, and assess long-term safety and cost-effectiveness. The Project on New Technology of Jiangsu Province, Clinical Competence Improvement Project of Jiangsu Province Hospital, National Natural Science Foundation of China, and 135 Project for Disciplines of Excellence–Clinical Research Incubation Project of West China Hospital funded the trial.