Summary
An artificial intelligence (AI) model analyzed electrocardiogram (ECG) recordings from adults in South Korea to distinguish those with and without left ventricular systolic dysfunction (LVSD), the American Heart Association said. The preliminary smartwatch ECG findings suggest the approach may help identify people for further screening with echocardiography, but classifications varied between watch brands and across repeated recordings.
Key Takeaways
- With the same AI score cutoff applied to both smartwatch brands, 200 of 2,211 clinic participants (9%) tested positive on one watch and negative on the other.
- Among 70 home-recording participants without LVSD, requiring positive results on at least 2 of 3 consecutive recording days reduced false positives from 18 to 9.
- Among all 146 home-recording participants, echocardiography confirmed LVSD in 81% of those with consistently positive results vs about 6% of those with consistently negative results.
Adults scheduled for echocardiography at a South Korean outpatient cardiology clinic had their smartwatch ECGs analyzed by an AI model that distinguished reduced heart pumping function about equally well on an Apple Watch and a Samsung Galaxy Watch. Researchers presented the preliminary findings Nov 9, 2026, at Scientific Sessions 2026 in Chicago, according to the American Heart Association’s release.
Researchers defined LVSD as a left ventricular ejection fraction of 40% or less and used transthoracic echocardiography to confirm the diagnosis. The American Heart Association noted that the abstract had not undergone peer review and that more research is needed before smartwatch ECG readings can replace traditional screening exams.
The 2,211 clinic participants recorded ECGs on both watches back-to-back under staff supervision. When investigators applied a cutoff set in advance using separate Galaxy Watch data to recordings from both devices, 200 participants (9%) received opposite classifications.
In the separate group of 146 adults who recorded at home, 108 recorded on at least 5 days in the first week. In that subset, a rule requiring positive results on at least 2 of 3 consecutive recording days cut false positives from 18 to 9 among the 70 participants without LVSD. The same rule identified 31 of 38 participants with LVSD vs 33 under the single-positive-day rule.
Across the full home-recording group, echocardiography confirmed LVSD in 81% of participants whose results were consistently positive and about 6% whose results were consistently negative. Nearly half (49%) had both positive and negative results, and 40% of that group had LVSD. Because many participants referred for echocardiography already had known heart failure and LVSD was more common than in the general population, the investigators also estimated results at lower prevalence.
“Larger studies are needed to determine how best to use these results to guide further evaluation,” says Hak Seung Lee, MD, chief medical officer of Medical AI Co., Ltd., which developed the model, and a cardiologist at the Digital Healthcare Institute, Sejong Medical Research Institute in Incheon, South Korea, in a release.
Incheon Sejong Hospital enrolled the clinic group between July 2023 and May 2024 and the home-recording group between July 2024 and December 2025. Both groups submitted 30-second, single-lead recordings within 14 days before or after echocardiography. At home, 94% used a Galaxy Watch, and participants recorded a median of 2.4 ECGs per day during the first week analyzed.
The American Heart Association noted that the single-hospital sample of patients referred for echocardiography may not reflect the general population and that the repeat-testing analysis was exploratory. Investigators excluded poor-quality recordings, which accounted for less than 3%, and staff reminded participants to record at home.
The investigators did not determine whether using the AI results led to earlier treatment, fewer hospitalizations, or improved survival. The clinic group had no 12-lead ECGs available for comparison.