The US Food and Drug Administration (FDA) has approved Medtronic’s Aurora EV-ICD (extravascular implantable cardioverter-defibrillator) MRI SureScan and Epsila EV MRI SureScan defibrillation lead to treat dangerously fast heart rhythms that can lead to sudden cardiac arrest. 

The Aurora EV-ICD system provides the life-saving benefits of traditional, transvenous ICDs with a lead (thin wire) placed under the breastbone, outside of the heart and veins. Medtronic’s Aurora EV-ICD delivers lifesaving defibrillation, anti-tachycardia pacing, and back-up pacing therapies via a device similar in size, shape, and longevity to traditional, transvenous ICDs.

FDA approval of the Medtronic Aurora EV-ICD system includes the system’s procedure implant tools and was supported by pivotal trial results showing the system’s safety and effectiveness, which were published in The New England Journal of Medicine. In the coming weeks, the Aurora EV-ICD system will be commercially available on a limited basis in the United States.

“The Aurora EV-ICD system is a tremendous step forward in implantable defibrillator technology,” says Bradley P Knight, MD, medical director of electrophysiology at Northwestern Medicine Bluhm Cardiovascular Institute and a co-author of the study, in a release. “Placing the leads outside of the heart, rather than inside the heart and veins, reduces the risk of long-term complications, ultimately allowing us to further evolve safe and effective ICD technology.”  

In the study, the device’s effectiveness in delivering defibrillation therapy at implant was 98.7%, and there we no major intraprocedural complications, nor any unique complications observed related to the EV ICD procedure or system compared to transvenous and subcutaneous ICDs. Additionally, 33 defibrillation shocks were avoided by having anti-tachycardia pacing—which paces the heart to interrupt and terminate a dangerous rhythm—programmed “on.” 

At six months, 92.6% of patients (Kaplan-Meier estimate) were free from major system and/or procedure-related complications such as hospitalization, system revision, or death.

ICDs are highly effective in providing life-saving therapy for patients at risk of sudden cardiac arrest, an electrical problem with the heart due to a dangerously fast heart rate (ventricular tachycardia) or irregular rhythm (ventricular fibrillation). If not treated immediately, sudden cardiac arrest is often fatal. Traditional ICDs typically are implanted below the collarbone, with the lead(s) threaded through the veins and into the heart.

“This FDA approval paves the way for patients to have a better overall experience with ICD therapy,” says Alan Cheng, MD, chief medical officer of the cardiac rhythm management business, part of the cardiovascular portfolio at Medtronic, in a release. “ICDs remain the gold standard for prevention of sudden cardiac death, and while the subcutaneous ICD avoids certain complications associated with transvenous defibrillators, it has limitations that may affect a patient’s comfort and quality of life. With the Aurora EV-ICD system, patients can benefit from the only ICD placed outside the vascular space that provides anti-tachycardia pacing and back-up pacing in a device that is nearly half the size and with 60% greater projected battery longevity compared to the competitor’s subcutaneous ICD.”

The Aurora EV-ICD system is similar in size, shape, and longevity to traditional, transvenous ICDs. Unlike traditional ICDs, the Aurora EV-ICD system is implanted below the left armpit (in the left mid-axillary region) and the lead is placed under the breastbone (sternum) using a minimally invasive approach. The Epsila EV defibrillation lead is placed outside of the heart and veins, helping to avoid certain complications associated with transvenous leads, such as vascular injury and vessel occlusion (narrowing, blockage or compression of a vein).

Medtronic will obtain real-world performance and safety data on the Aurora system in the Enlighten global post-approval registry, a prospective, non-randomized, observational, multicenter study, expected to last five years and enroll approximately 1,000 patients.

The Aurora EV-ICD system is indicated for patients who are at risk of life-threatening arrhythmias and who have not had a prior sternotomy and do not need chronic bradycardia (abnormally slow heartbeat) pacing.